Beyond a depth of 8 measured from the leading edge the 27 minimum high knee clearance can reduce 18 to the 9 toe space over a 3 span.
Restroom ada lavatory clearance.
Minimum clearances between the face of the toilet fixture and the wall or nearest obstruction element are at least 24 61 cm but are recommended to be 36 91 cm.
Ada standards for accessible design can be downloaded from www ada.
The department of justice published revised regulations for titles ii and iii of the americans with disabilities act of 1990 ada in the federal register on september 15 2010.
According to the 2010 update to adaag the basic ada guidelines for a single user restroom are.
When the knee and toe depth exceeds the 17 minimum the additional space must provide full knee clearance at least 27 high.
30 inch by 48 inch access to the sink the door can t swing into this rectangle.
A portion of the clear floor space may be located under fixtures lavatories or accessories as long as the required knee and toe clearance is provided fig.
Keep the lavatory outside the water closet clearance so that space is available for side transfers.
Lavatory installation an accessible lavatory at least one in each bathroom must extend at least 17 inches from the back wall and have a clearance of at least 29 inches from the bottom of the sink apron to the finished floor.
A compliant lavatory is permitted on the rear wall 18 min.
From the water closet centerline if the clearance at the water closet is at least 66 instead of 56 deep 604 3 2 ex.
For information about the ada including the revised 2010 ada regulations please visit the department s website www ada gov.
Toilet stall doors including door hardware shall comply with 4 13.
Or for answers to.
Specific questions call the toll free ada information line at 800 514 0301 voice or 800 514 0383.
Clearances around toilets and water closets wcs can be measured from the face of the fixture or from its center line and are used to best service the toilet user.
Turning space 304.
In standard stalls the front partition and at least one side partition shall provide a toe clearance of at least 9 in 230 mm above the floor.
Dwelling unit water closet and lavatory recommendation.
These regulations adopted revised enforceable accessibility standards called the 2010 ada standards for accessible design 2010 standards or standards.
All bradley lavatory fixtures are designed so that ada toe and knee clearance starts at the wall.
If the depth of the stall is greater than 60 in 1525 mm then the toe clearance is not required.
14 and many others.
The measurement starts from the point where a person has 9 inch vertical clearance for their feet and 27 inch vertical clearance for their knees.